Digital Monitoring Products XR500 Series Programming Guide
72
Appendix
23.14 Area Account Number Messages
XR500 systems send an area account number instead of the system account number with the following panel
messages/events based on the area assigned to the zone that initiated the alarm:
WARNING: Alarm Bell Silenced (S34)
Abort Signal Received (S45)
Cancel Signal Received (S49)
ALERT: System Recently Armed (S78)
ALERT: Exit Error (S80)
ALARM: Verify Signal Received (S96) (not currently sent on area arming systems)
The XR500 has always sent the area account number for the following messages:
Zone event messages for all non-24 hour zones assigned to an area
Arming
Disarming
The XR500 sends the following messages using the area account number based on the lowest area number in
Display Areas programming from the keypad being used:
User Code Add/Change/Delete
Door Access/Denied
User 1 Ambush and Early Morning Ambush
System Test Begin/End
Unauthorized Entry
Service Code and Service Request
The XR500 sends the following messages using the area account number based on the area number:
Late to Arm for area schedules