XR500 Series Programming Guide Digital Monitoring Products
47
Zone InformatIon
Zone Information
19.1
ZONE INFORMATION
Zone Information
Zone Information allows you to dene the operation of each protection zone used in the
system. All protection zones, whether located on a panel, Security Command keypad, or
zone expander are programmed the same way.
19.2
ZONE NO: -
Zone Number
Enter the number of the zone you intend to program. Available zone numbers are shown
in the table below. The keypad zone numbers begin with the keypad address and are
followed by the particular zone from that keypad. For example, a 7073 at keypad address
7 would provide zones 71, 72, 73, and 74.
Press COMMAND to enter a zone name.
Address Programming Zone Number
Panel 1-10
1 11-14
2 21-24
3 31-34
4 41-44
5 51-54
6 61-64
7 71-74
8 81-84
9 91-94
10 101-104
11 111-114
12 121-124
13
131-134
14 141-144
15 151-154
16 161-164
1100 Series Key Fob 400-449
LX-Bus 1 (A) 500-599
LX-Bus 2 (B) 600-699
LX-Bus 3 (C) 700-799
LX-Bus 4 (D) 800-899
LX-Bus 5 (E) 900-999
Note: For 1100 Series Key Fob zones (400-449), programming continues at the 1100 Series
Key Fobs Section.
19.3
* UNUSED *
Zone Name
Zone names can have up to 32 alphanumeric characters. A name must be given to each
zone in the system. The name can display at the keypads during arming and disarming
so the user does not have to memorize zone numbers. Users can asso ciate a zone name
with a particular protection point. A zone that is not part of the system must be marked
unused.
To add a zone name to the system, press any Select key and then enter up to 32
characters for the new zone name. Press COMMAND to continue.
To mark a zone unused, de lete the old name by pressing a top row Select key, then press
the COMMAND key. The pro grammer auto matically pro grams the name as * UNUSED *. If
you have already cleared Zone Information during Initialization, the zones is marked *
UNUSED *.