Digital Monitoring Products XR500 Series Programming Guide
38
StatuS LiSt
Status List
15.1
STATUS LIST
Status List
This function allows you to select the zone alarms and troubles, and system monitor
troubles displayed at the keypads. The Status List function operates automatically when
the keypad is not performing any other function.
The keypad stays in the Status List until the user arms or disarms or selects a menu
option. Status List al ternates with the Armed Status on keypad addresses selected in the
Menu Display - Armed Status section. You can choose to have Sys tem Monitor troubles
placed in the list, the differ ent zone types placed in the list, and at which keypad
addresses they dis play.
To select a keypad, enter the device number (keypad address) using the digit keys on
the keypad. When a keypad is selected, an asterisk appears next to the keypad address.
Enter the number again to deselect the keypad. Press the COMMAND key to display the
next set of keypads (9 through 16). Refer to the Multiple Displays section at the beginning
of this document.
15.2
DISPLAY KEYPADS:
Display Keypads
This option denes which keypad ad dresses display the various status information. Any
combina tion of addresses can be en tered to display the status items that follow. If you do
not want a particular status item to dis play, do not enter any ad dresses.
15.3
SYSTEM TROUBLES:
System Monitor Troubles
Species the keypad addresses (1 through 16) where any trouble on a System Monitor
dis plays. The System Monitors include the following:
AC Power
• Battery Power
• Closing Check
• Panel Box Tamper
• Phone Line 1
• Phone Line 2 (requires the 893A Dual Phone Line Module)
• Wireless Receiver Trouble
• Wireless Jamming Trouble or Alarm
The System Monitor name is placed in the Status List and the keypad steady trouble
buzzer sounds. The buzzer remains on until any keypad top row Select key is pressed.
The name remains in the list until the condition is re stored. The buzzer sounds at 10:00
am daily until the system trouble is cleared from the Status List.
15.4
FIRE ZONES:
Fire Zones
Species the keypad addresses (1 through 16) where all re zone alarms and troubles
display. The zone name displays and, if it is a trouble condition, the keypad steady
trouble buzzer sounds. The buzzer remains on until any top row Select key is pressed and
a user code is entered. If a trouble condition remains in the display, the buzzer sounds at
10:00 am daily until the trouble is cleared from the Status List.
When using LCD Keypads, the panel provides distinct speaker tones from the keypad for
Fire:
On - Fire zone alarm and Bell Output or Fire Bell Output is ON.
Off - Alarm Silence