SyStem RepoRtS
System Reports
8.1
SYSTEM REPORTS
System Reports
Select specic system reports the panel sends to the receiver.
8.2
ABORT NO YES
Abort Report
YES allows the panel to send an alarm abort report to the receiver any time an area
is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff
Time has not expired. After disarming an area, if any other area remains armed and has
zone(s) in alarm, the alarm abort report is not sent.
If the communication type is set to DD, a Warning: Alarm Bell Silenced report is also sent
if the alarm bell is silenced.
Note: Abort Reports are not sent for Fire, Fire Verify, or Supervisory type zones.
8.3
RESTORAL: YES
Restoral Reports
This option allows you to control when and if a zone restoral report is sent to the central
station receiver. Press any Select key to display the following options:
NO YES DISARM
NO - Disables the zone restoral report option. Zones continue to operate normally but do
not send restoral reports to the receiver.
YES - Enables the zone restoral report option. Zone restorals are sent whenever a zone
restores from a trouble or alarm condition.
DISARM - Causes the panel to send restoral reports for a non-24-hour zone whenever a
zone that has restored from a trouble or alarm condition is disarmed. All 24-hour zones
send restoral reports as they restore.
Note: For UL applications, Restoral Reports must be set to YES.
8.4
BYPASS NO YES
Bypass Reports
YES allows the panel to send all zone bypasses, resets, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user name
and number of the individual operating the system. Reports are only sent if O/C User in
Communications is set YES for Receiver 1 or Receiver 2.
8.5
SCHD CHG NO YES
Schedule Change Reports
YES allows the panel to send all schedule changes to the receiver. The report includes
the day, opening time, closing time, extend schedule time, and the user name and
number of the individual making the change. Schedule changes made through Remote
Link™ are not sent to the printer or Display Events.
8.6
CODE CHG NO YES
Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the receiver.
The code change report includes the user name and number added or deleted and the
user name and number of the individual making the change. Code changes made through
Remote Link™ are not sent to the printer or Display Events. Reports are only sent if O/C
User in Communications is set YES for Receiver 1 or Receiver 2. The default setting is YES.
8.7
ACCESS KEYPADS:
Access Keypads
Select the keypad addresses (1 through 16) that send door access reports to the receiver.
Enter the keypad number using the digit keys. An asterisk next to the number indicates
that the keypad is selected. Press COMMAND to display the next set of keypads.
A report is sent with each door access made from the selected keypads. Keypads at
addresses not selected still operate the door relay but do not send access reports. The
report includes the user number, user name, keypad address, and device name.
8.8
AMBUSH NO YES
Ambush
YES allows an ambush report to be sent anytime user code number 1 is entered at a
keypad. NO disables the ambush report and allows user number 1 to operate the same as
all other codes.