Digital Monitoring Products XR500 Series Programming Guide
36
Output GrOups
Output Groups
13.1
OUTPUT GROUPS
Output Groups
This function allows you to assign outputs to groups. Output groups can be assigned to
other areas of programming such as Output Options or Alarm Action of Zone Information,
just like single outputs are assigned. This allows the entire group of outputs to turn on
and off as required by the programming option.
13.2
GROUP NO: -
Group Number
Enter a group number from 1 to 20. Up to 20 different groups may be assigned.
13.3
GROUP NAME X X
Group Name
The group name displays. To change the default name, press any top row Select key then
enter up to 32 characters for the group name. Press COMMAND to enter the outputs to be
assigned to the group.
13.4
OUTPUT NO 1: 0
OUTPUT NO 2: 0
OUTPUT NO 4: 0
OUTPUT NO 5: 0
OUTPUT NO 3: 0
OUTPUT NO 7: 0
OUTPUT NO 8: 0
OUTPUT NO 6: 0
Output Number
Enter the Output number. Entry range is 1 to 6, 450 to 474, 480 to 499, 500 to 999
(outputs), D1 to D16 (doors), and G1 to G20 (groups). The maximum number of outputs
that can be assigned to a specic group is eight.
An output group may be assigned as one of the output numbers in another output group.
Example: Output Group 1 consists of only four assigned outputs. Output Group 1 could
be assigned as one output in Output Group 2. Output Group 2 could still have 7 other
outputs assigned to that group. When Output Group 2 is turned on, 11 outputs could
be turned on. This allows Output Groups to be assigned within other Output Groups
providing many combinations.
Output groups 1 to 10 can be assigned by a user prole for applications such as elevator
control. See the XR500 User’s Guide (LT-0683) Output Group section for additional
information.
Output groups 11 to 20 cannot be assigned to a prole and are available for installation
applications such as special lighting, etc. To assign these groups to a prole, use Remote
Link™ or System Link™ software from DMP.