Digital Monitoring Products XR500 Series Programming Guide
10
CommuniCation
3.23
SUB CODE NO
Substitution Code
This option displays when the Communication Type is NET, CELL or 232. The Panel
Substitution Code increases the level of security by helping to ensure that the panel
sending the message to the receiver has not been substituted by another panel. The
default is NO.
Select YES to send a substitution code with every message.
Select SHARED (SHR) to use the same substitution code as operating in the previous path.
3.24
232 COMM PORT: O
232 Communication Port
This option displays when Communication Type is 232.
This option sets the physical RS-232 port to the on-board connector or one of the DMP
Model 461 Interface Adaptor Card slots labeled A, B, C, D, or E. Use slot A if using a 462N
Network Interface Card with or without the 461 card.
Enter O to use the on-board connector. Set the XR500 Series panel J23 jumper to R and
briey reset the panel using the J16 jumper to activate RS-232 operation. Default is O
(On-board).
3.25
-
-
232 SETUP:
232 Setup String
This option displays when the Communication Type is 232. Enter up to two lines of 16
characters to equal up to 32 characters for the destination address that may include an
IP address.
Example: If using a DMP iCOM, enter AT#UCXXX.XXX.XXX.XXX#PPPPP where X
is the IP address and P is the port number.
3.26
893A: NO YES
893A
This option displays when the Communication Type is DD or CID.
The 893A option allows reports to be sent to the receiver on a second DD line using the
893A module. Default is No.
When using this option, Test Report messages (S07 Automatic Recall Test or S88
Unrestored System Recall Test) are sent to the receiver at the frequency programmed in
Test Frequency, alternating between the rst and second phone line.
For example, a DD path with an 893A module set for daily test report frequency sends a
test report through phone line 1 one day and phone line 2 the next day.
If the 893A option is set to YES, enter up to a 3-digit prex to be dialed before the
second phone number. If no prex is entered, the second phone number is dialed as
originally entered.
3.27
ALARM SWITCH: 1
Alarm Switch
This option displays for DD or CID Communication Types.
Enter the number of attempts to send an alarm message before switching to the next
path. Range is from 1 to 10. All non-alarm messages are sent for 10 attempts on the
dialer before a switch is initiated. If the path immediately following this channel is not a
backup path, this option has no effect. Default is 1.
3.28
DUPLICATE ALARMS
Duplicate Alarms
This option displays for BACKUP paths. If Yes is selected, the current backup path
duplicates all alarms occurring on its group primary path. Default is No.
3.29
ALARM YES
Alarm Reports
This option displays when the Path Type is Primary. All backup paths within the group
follow the same programming for Alarm Reports. Default is Yes.
NO YES FIRE
When YES is selected, the following reports are sent to the receiver for all zone types:
• Alarm • Bypass • Reset • Restore
When FIRE is selected, the following reports are sent for Fire, Fire Verify and Supervisory
Zones:
• Alarm • Bypass • Reset • Restore
D E
O A B C
NO YES SHARED
NO YES
-