Digital Monitoring Products Canadain XR500 Manual de instrucciones Pagina 63

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 62
XR500 Series Programming Guide Digital Monitoring Products
53
Zone InformatIon
19.11.8
BUTTON
PRESS TIME: XXXXX
Button Press Time
This option species the amount of time (SHORT or LONG) the user must press the
button before the key fob sends a message to the wireless receiver. The default
press time displays. Press any Select key to set the Button Press Time for Arm,
Disarm, Toggle, Status, Output, and Sensor Reset.
Note: The Button Press Time is not programmable on Panic (PN or PN2), Emergency
(EM or EM2) or Unused (UN) zones. For those zones the button press time is always
two (2) seconds.
PRESS TIME:
SHORT LONG
SHORT - Press the button for one-half (1/2) second to send the message to the
wireless receiver.
LONG - Press the button for two (2) seconds to send the message to the wireless
receiver.
19.11.9
ARM/DIS AREAS:
Arm/Disarm Area Selection
In an Area system or Home/Sleep/Away with Guest system, this species the areas
to be armed/disarmed by the Key Fob button being programmed. To select an area
between 1 and 32, enter the area number using the keypad digit keys. Default is no
areas enabled.
In order to arm or disarm selected areas, the Prole assigned to the User Number
needs to have the same area numbers selected. Any area may be selected at Arm/
Disarm Areas but only matching area numbers are armed or disarmed when the
specic button is pressed. For example, in Areas selection, areas 1, 3, and 7 are
selected. In the User Prole Arm and Disarm Areas, areas 1, 2, 4, and 7 are selected.
When the user presses the button to Arm or Disarm area(s), only matching areas 1
and 7 Arm/Disarm.
Note: When more areas are selected at Arm/Disarm Areas than are authorized in
the User Prole, in the future the user can be given access authority to additional
areas through the User Prole without requiring additional panel programming to
select Arm/Disarm Areas. See User Proles in the Appendix or refer to the XR500
Series User’s Guide (LT-0683).
ARM AREAS: PERIM
In an All/Perimeter or Home/Sleep/Away system, this species the area to be armed
by the Key Fob button being programmed. For All/Perimeter systems, choose PERIM
or ALL, for Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
Note: Areas 3 and higher in an All/Perimeter system, and areas 4 and higher in a
Home/Sleep/Away system are not available for use.
After selecting the areas, for one-button key fobs the Zone No.: option displays. For
two-button or four-button key fobs, the Key Fob Button Selection option displays to
program additional buttons.
19.11.10
OUTPUT NO: XXX
Output Number
You can specify a relay output to operate when OUT (Output), PN (Panic), PN2
(Panic 2), EM (Emergency), or EM2 (Emergency 2) is selected for a key fob Button
Action and the button is pressed. Valid range is 1 to 6, 500 to 999,
D1 to D16, or G1 to G20. For an output turned on by a PN, PN2, EM, or EM2 button
action, the output turns off when any area is disarmed.
To enter an output number, press a top row Select key followed by the output
number. Press the COMMAND key.
Vista de pagina 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 83 84

Comentarios a estos manuales

Sin comentarios