Digital Monitoring Products XR500 Series Programming Guide
50
Zone InformatIon
DMP Wireless
For a DMP 1100X Wireless Receiver set the House Code from 1 to 50. See House Code programming in System
Options. Zones 500 through 999 can be programmed as Wireless zones. Set the XR500 Series panel J23 jumper to
X to enable on-board DMP Wireless operation. Briey reset the panel using the J16 jumper to activate Wireless
operation. Refer to the XR500 Series Installation Guide (LT-0681).
For an 1100 Series Key Fob see section 19.11.
For an FA Series Remote Wireless Receiver see section 19.12.
NOTE: All wireless programming is stored in the XR500 Series panel. The 1100X Wireless Receiver obtains the
necessary programming information from the panel each time the receiver powers up, when the programmer
STOP routine is selected or the panel is reset. The receiver memory refresh takes up to 10 seconds to complete
depending on the number of wireless zones programmed and the Red LED remains on during this time. Normal
receiver operation is inhibited during the memory refresh period.
19.10 Wireless
Select YES to program this zone as a DMP wireless zone. You must program the
wireless House Code prior to adding DMP wireless zones to the system. See House Code
programming in System Options. Default is NO.
19.10.1
TRANSMITTER
SERIAL#: XXXXXXXX
Serial Number Entry
Enter the eight-digit serial number found on the wireless device.
ALREADY IN USE
ZONE NUMBER: XXX
This message displays when the serial number is already programmed for another
zone. The programmed zone number displays.
19.10.2
TRANSMITTER
CONTACT:XXXXXXXX
Contact
This option displays if the serial number entered is for an 1101 or 1103 Universal
Transmitter or 1114 Wireless Four-Zone Expander. Press any top row key to select
the contact.
TRANSMTR CONTACT
INT EXT
This option displays when programming an 1101 or 1103 Transmitter. Select INT to
use the internal reed switch contacts. Select EXT to connect an external device to
the 1101 or 1103 terminal block. Default is INTERNAL.
By allowing both of the Model 1101 or 1103 transmitter contacts (INT and EXT) to be
used at the same time, two zones may be programmed from one transmitter. When
using both contacts, you must use consecutive zone numbers. Zones 531 and 532 or
zones 890 and 891 are acceptable zone assignments.
For example, program transmitter serial number 01345678 as Zone 521 with an INT
contact type and Zone 522 with an EXT contact type. The same serial number is
used for both zones.
Note: When using the 1103 Universal Transmitter in a UL listed Commercial Burglary
installation, the external contact cannot be used.
TRANSMTR CONTACT
1 2 3 4
This option displays when programming the 1114 Wireless Four-Zone Expander with
four input contacts. The same serial number is used for all four contacts. Select the
contact number to program. When using the contacts, you must use consecutive
zone numbers. Default is Contact 1.
For example, use serial number 08345678 to program Contact 1 for Zone 561,
Contact 2 for Zone 562, Contact 3 for zone 563, and Contact 4 for zone 564.
A tamper on the 1114 is transmitted as the zone number assigned to Contact 1.
ALREADY IN USE
ZONE NUMBER: XXX
This message displays when the Contact is already programmed for another zone.
The programmed zone number displays.
ZONE INFORMATION
NORM OPN NO YES
This option only displays when EXT is selected as the Contact type. For external
devices connected to the 1101 or 1103 terminal block, select NO to use normally
closed (N/C) contacts. Select YES to use normally open (N/O) contacts. Default is
NO.
Note: For UL listed installations, set Normally Open to NO.
19.10.3
TRANSMITTER
SUPRVSN TIME: 240
Supervision Time
Press any top row key to select the supervision time required for the wireless zone.
Press COMMAND to accept the default time. Default is 240 minutes.
Note: Refer to the Wireless Check-in and Supervision Time Denitions section of the
Appendix for supervision information.
ZONE INFORMATION
WIRELESS? NO YES