XR500 Series Programming Guide Digital Monitoring Products
41
PC Log RePoRts
PC Log Reports
17.1
PC LOG REPORTS
PC Log Reports
This section allows you to program the types of PC Log Reports the panel sends through
the 462N Network Interface Card or through the J21 Serial Connector directly on the
XR500 Series panel. The reports include information such as the type of activity, time
and date of the activity, and user name and number. These data reports can be accessed
from a PC using the Advanced Reporting Module. See the Installation Guide (LT-0681) for
detailed J21 setup information or the User’s Guide (LT-0683) for more information.
Note: The network connection that sends PC Log Reports is not monitored for network
trouble. The PC Log Reports option should NOT replace the primary communication
method or act as a backup communication method.
If there is trouble with the network connection, the panel continues to attempt to
send the PC Log Reports until the connection is reestablished. The panel then sends the
reports. A Network Trouble message is NOT sent if the connection is lost since this report
tool is not designed to be monitored by a receiver. The PC Log Reports have the lowest
priority of panel reports sent.
For information about the 462N card capabilities with PC Log Reports and Network
Communication method, see 462N Card Examples in the Appendix.
Note: The PC Log Address String entered CANNOT be the same as that entered in
Communication.
17.2
COMM TYPE: NONE
Communication Type
NONE NET 232
Select the Communication Type to send the PC Log Reports. Default is NONE.
17.3
NET IP ADDRESS
Net IP Address
This option displays when the Communication Type for PC Log Reports is NET. Enter the
IP address containing up to 16 characters. The Net IP Address must be unique and cannot
be duplicated on the network. Enter all 12 digits and leave out the periods. For example,
enter IP address 192.168.0.250 as 192168000250. The periods display automatically.
17.4
NET PORT 2001
Net Port
This option displays when Communication Type for PC Log Reports is Net. Enter the Port
number. Valid numbers are from 0 to 65535. Default is 2001.
17.5
232 COMM PORT: O
232 Communication Port
This option displays when Communication Type for PC Log Reports is 232. To enable PC
Log Reports, select either the on-board connector (O) or select A, B, C, D or E for the
corresponding slot in use on the DMP Model 462N Network Interface card. The slots are
labeled from left to right, beginning with A. Default is O.
Set the XR500 Series panel J23 jumper to R and briey reset the panel using the J16
jumper to activate RS-232 operation.
17.6
232 SETUP:
232 Setup
This option displays when Communication Type for PC Log Reports is 232. Enter up to 32
characters.
17.7
ARM/DIS NO YES
Arm and Disarm Reports
Sends arming, disarming and Late to Close events. Includes the area number, name and
action, the user number and name, and the time and date.
17.8
ZONE NO YES
Zone Reports
Sends changes in the status of active zones. Includes the zone number, name, type, the
action (alarm, trouble, bypass, etc.), user number (if applicable), and area name. For a
Walk Test, Verify and Fail messages are sent for each zone.
17.9
USR CMDS NO YES
User Command Reports
Sends user code changes, schedule changes, and door access denied events.
17.10
DOOR ACS NO YES
Door Access Reports
Sends door access activity: door number, user number and name, and time and date.