XR500 Series Programming Guide Digital Monitoring Products
59
StoP
Stop
20.1
STOP
Stop
Save Programming
WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE RUN
AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE THE
PROGRAMMING CHANGES.
At the STOP option, pressing any Select key allows you to exit the Programmer function
of the panel. When selected, the panel performs an internal reset and exits the
programmer.
The STOP routine causes the following conditions to occur:
All 1100 Series DMP Wireless transmitters are reset to NORMAL
• The panel Status List is cleared
During the reset, all keypad displays are momentarily blank for two seconds. After the
reset, the programming function terminates and the keypads return to the status list
display.
The STOP option does not disarm the system. Any new areas or zones that were added
during programming are not armed until the system is disarmed and armed again.
Missing LX-Bus™ Modules Displayed
The Programmer includes a feature following the STOP routine that displays the name of
any programmed LX-Bus module not currently connected to the panel. For example, if
you had enabled any LX-Bus options and not yet installed a 481 LX-Bus Expansion Card,
after the STOP routine the panel displays NO LXBUS CARD. This is a helpful reminder to
install the card. This feature can also be a troubleshooting tool to indicate a problem
if you installed the card and this message still displays. The following list shows the
different messages and their associated LX-Bus cards.
Keypad Display Missing Card
NO LXBUS CARD 481 LX-Bus™ Expansion Card
NO PRINTER CARD 462P Printer Interface Card
NO HOST CARD 462N Network Interface Card
(with NETWORK communication selected)
The above messages clear automatically from the keypad after a few moments.
Power Up
When the XR500 Series panel is powered up after an AC power failure, any zone
transitions are not recognized for 60 seconds. Normal zone processing resumes at the end
of the 60 seconds.
Set Lockout Code
21.1
SET LOCKOUT CODE
Set Lockout Code
Pressing COMMAND at the STOP option displays SET LOCKOUT CODE. This allows you to
program a code that is then required to gain access to the panel internal Programmer
through the keypad. You can change this code at any time to any combination of numbers
from three to ve digits long. You do not need to enter leading zeros when using the
lockout code. Initializing the panel does not clear a Lockout Code. Lockout Codes can be
changed through Remote Link.
Once you have changed the code, it is important to write it down somewhere and store it
in a safe place. Lost Lockout Codes require the panel to be sent back to DMP for repair.
You may cancel a Lockout Code by entering 00000 at the Set Lockout Code command.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.
Set Lockout code