Digital Monitoring Products XR500 Series Programming Guide
16
Device Setup
When all areas accessed by a door are armed, the door is locked by the panel.
Note: For an All/Perimeter, Home/Sleep/Away, or Home/Sleep/Away with Guest
system, Access Areas should be left at factory default settings.
6.8 Egress Areas
Press the COMMAND key to program Egress Areas. To select an area, enter the area
number using the digit keys on the keypad. When an area is selected, an asterisk appears
next to the area number. Enter the number again to deselect the area. Press COMMAND
to display the next set of areas. Refer to the Multiple Displays section at the beginning of
this document.
Note: For an All/Perimeter, Home/Sleep/Away, or Home/Sleep/Away with Guest
system, Egress Areas should be left at factory default settings.
Note: If an area is programmed as an access area, it cannot be programmed as an egress
area and therefore does not display during Egress Areas programming.
Use this option to detect Anti-passback violations. Anti-passback requires a user to
properly exit (egress) an area they have previously accessed. If users fail to exit through
the proper card reader location they are not granted access on their next attempt. Users
must have matching access area numbers assigned to their prole, to receive a door
access at this device. If the user is programmed for Anti-Pass YES, then the user is logged
out of all matching areas. This allows the user to again access the area. See Access Areas
section.
If you do not enter any area numbers, all users with Door Access authority receives a
door access without regard to schedules. If you are not using the Anti-Pass feature leave
Egress Areas blank.
6.9
DISPLAY AREAS:
Display Areas
*1 *2 *3 *4
*5 *6 *7 *8
*9 *10 *11 *12
*13 *14 *15 *16
*17 *18 *19 *20
*21 *22 *23 *24
*25 *26 *27 *28
*29 *30 *31 *32
Press the COMMAND key to program Display Areas. To select an area between 1 and 32,
enter the area number using the keypad digit keys. When an area is selected, an asterisk
appears next to the area number. Enter the number again to deselect the area. Press
COMMAND to display the next set of areas. Default is all area numbers. Refer to the
Multiple Displays section at the beginning of this document.
Display Areas allows the XR500 Series burglary activities to be segmented so that only
specic area(s) and their associated operation appear at a particular keypad. Area
number(s) selected in this eld affect the way users interact with the system from this
particular device. For example: Program Device 1 to show only the zone activities and
armed status of Area 1.
Enter the area number(s) that this keypad is to display. This allows specic area control from
specic keypads, as well as annunciation of zones assigned to those area(s). When Display
Areas is left defaulted (all areas selected), Menu Display and Status List items determine
whether zone alarms and troubles display at this device, regardless of area assignment. Also,
all system areas may be armed and disarmed from this device.
Note: For an All/Perimeter or Home/Sleep/Away system, Display Areas should be left
at factory default settings.
For Home/Sleep/Away with Guest arming systems, the Display Areas selection determines
which system the keypad arms and disarms. With areas 1, 2 or 3 being the rst areas
selected, the keypad is assigned to the Main system. With area 4, 5 or 6 being the rst areas
selected, the keypad is assigned to the Guest 1 system. With area 7, 8 or 9 being the rst
areas selected, the keypad is assigned to the Guest 2 system. Keypads can have additional
areas assigned for Event Display.
User Action Allowed
When an area(s) is selected, the following user actions are allowed:
• Arming or Disarming of the area(s) selected from the ARM or DISARM menu
• Alarm Silence for the area(s) selected
• Zone Bypass of zones assigned to the area(s) selected
• Zone Monitor of zone assigned to the area(s) selected
• Shift schedule changes allowed for the area(s) selected
• Closing Check Schedule Extend is allowed for the area(s) selected
• Schedules changes are allowed for devices that have a matching area(s)
as dened in Device Access Areas
• Door On/Off Menu operation is allowed for devices that have a matching area(s)
as dened in Device Access Areas
EGRESS AREAS: