XR500 Series Programming Guide Digital Monitoring Products
57
Zone InformatIon
19.21
RETARD NO YES
Zone Retard Delay
When you select YES, the zone operates with the zone retard delay. The retard func tions
only in zone short condi tions.
The zone must re main shorted for the full length of the re tard de lay before the panel
recognizes its condition. If you select NO, the zone operates without a retard delay.
Note: For UL installations, Zone Retard Delay shall not be used for burglary zones.
19.22
PRESGNL KEYPADS:
Presignal Keypad Addresses
You can enable any combina tion of keypad addresses to sound a presignal tone during the
time a zone is in retard delay. The presignal tone si lences when the zone restores or the
re tard delay expires.
To en able a presignal ad dress, press any top row Select key followed by the number of
the keypad address. You can enable the presignal for all 16 keypad addresses. To disable
a presignal address press the matching number digit again. Press the COMMAND key when
the address selection is complete. The Presignal option is only displayed when Retard is
selected as YES.
19.23
FAST RSP NO YES
Fast Response
Select YES to provide a zone response time of 167ms. Select NO to provide a normal zone
response time of 500ms. Zones 500 to 999 have a xed response time and do not display
this option.
19.24
CRS ZONE NO YES
Cross Zone
Select YES to enable cross zoning for this zone. Cross zoning requires one or more armed
zones to fault within a programmed time before an alarm report is sent to the receiver.
When the rst cross zoned zone trips, the cross zone time specied in System Options
begins to count down. When a second cross zoned zone trips or the rst zone trips a
second time before the end of the count down, the bell action assigned to the zone
activates and the panel sends an alarm report for both zones.
If no other cross zoned zone trips before the cross zone time expires, the panel sends
only a zone fault report to the receiver.
Cross zoning is not compatible with all zone types: You can not enable cross zoning for
Fire verify zones or for any Fire zones that have Retard Delay enabled.
Note: For UL Installations, Cross Zoned zones must protect the same area.
19.25
PRIORITY NO YES
Priority
Select YES to provide additional protection for the premises by requiring this zone to be
in a normal condition before its assigned area can be armed.
19.26 Fire Panel Slave Input
This option is available on Fire Zones (FI) only and allows a re zone the ability to
provide slave communication operation for a separate re alarm control panel. If YES,
this zone will transmit a restoral immediately when restored by the re panel being
monitored. A sensor reset is not required to generate the restoral message.
If NO, this zone will operate as a standard re type zone and a sensor reset is required
before the zone will return to normal. Default is NO.
19.27 Area Follower
Allows Night, Day, Aux 1, or Aux 2 burglary zones to be delayed by following any exit or
entry delay that is currently running in the area that is specied. Default is 0.
19.28 Zone Real-Time Status
Selecting YES allows Real-Time Status reports, such as Door Open or Closed with zone
number, to be sent using PC Log reporting. Selecting NO disables Real-Time Status for this
zone. Default is NO.
19.29
ZONE AUDIT DAYS:
Zone Audit Days
Enter the number of days (0 to 365) allowed to elapse without the zone being tripped
before a fault message is sent. The message is sent to the receiver(s) programmed to
receive Supervisory/Trouble Reports at 10:00 am following the expiration of the timer.
Each time the zone is tripped, the Zone Audit Days timer restarts and begins to countdown
the number of days programmed. After the countdown expires, a fault message is sent
and the Zone Audit Days timer restarts and begins to countdown the number of days
programmed. Available for all zone types except re and re verify. Enter 0 (zero) to
disable this function. Default is 0 (zero).
FOLLOW AREA: 0
ZONE REAL-TIME
STATUS
NO YES
FIRE PANEL SLAVE
INPUT: NO YES
0