Digital Monitoring Products XR100 Series Programming Guide
64
Appendix
21.10 Zone Type Descriptions
ThissectiondescribesapplicationsforthedefaultzonetypesinZoneInformationprogramming.
-- (Blank Zone)
Customizablezonetype.Bydefault,noactionsareprogrammedtooccurwithBlankZone.Azonename
mustbeenteredtousethiszonetype:Thiszonetypeisnotthesameasan*UNUSED*zone.
NT (Night Zone)
Controlled instant zone used for perimeter doors and windows and interior devices such as PIRs and
Glassbreakdetectors.
DY (Day zone)
Usedforemergencydoorsorredoorstosoundthekeypadbuzzeranddisplaythezonenamewhenthe
zone is faulted. Day zones also send alarm reports to the receiver during the system armed periods.
EX (Exit zone)
Initiates the entry delay timer when its assigned area is fully armed. Also, can initiate an exit delay timer
to allow a user to exit an area after the arming process starts.
PN (Panic zone)
Usedforconnectingtomechanicaldevicesthatallowausertosignalanemergencyalarm.Paniczonescan
provide either a silent or audible alarm with or without reporting to a central station receiver.
EM (Emergency zone)
Theseareusedforreportingmedicalorothernon-panicemergenciestothecentralstationreceiver.
SV (Supervisory zone)
Usedtoprovide24-hourzonesupervisiontodevicesassociatedwithresystems.Typicalapplicationsare
tamperswitchesonPostIndicatorValves(PIVs),gatevalves,andlowandhightemperaturegauges.
FI (Fire zone)
Usedforanytypeofpoweredormechanicalredetectiondevice.Typicalapplicationsareforsmoke
detectors,sprinklerowswitches,manualpullstations,andbeamdetectors.Retard,crosszoning,and
presignal options are available for the Fire zone type.
FV (Fire Verify zone)
Usedprimarilyforsmokedetectorcircuitstoverifytheexistenceofanactualrecondition.WhenaFireVerify
zoneinitiatesanalarm,thepanelperformsaFireReset.IfanyFireVerifyzoneinitiatesanalarmwithin120
secondsafterthereset,analarmisindicated.Ifanalarmisinitiatedafter120seconds,thecyclerepeats.
A1 and A2 (Auxiliary 1 and Auxiliary 2)
These zones are similar to a Night zone and are typically used to protect restricted areas within a
protected premises.
AR (Arming zone)
This zone allows you to connect a keyswitch to a zone and use it to arm and disarm one or more areas.
Prole
# Prole Name
Arm/Disarm
Areas Access Areas
Output
Group
Arm
Disarm
Alarm Silence
Sensor Reset
Door Access
Armed Area
Outputs On/Off
Zone Status
Bypass Zones
Zone Monitor
System Status
System Test
User Proles
User Codes
Schedules
Time
Display Events
Service Request
Fire Drill
Extend Schedules
Temp User Code
Anti-passback
Easy Arm/Disarm
Shift/Time
Access
Re Arm Delay
Sec Language
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
1 2 3 4 A
Vista de pagina 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 78

Comentarios a estos manuales

Sin comentarios