XR100 Series Programming Guide Digital Monitoring Products
59
Appendix
Serial Number
Thisnumberisthenetworkcommunicatorserialnumber.Referencethisnumberforcommunicatordate-of-
manufacture, hardware version, etc. Press any top row Select key to display the Serial Number. Press the
COMMAND key to view the next option.
Current Flash
ThisoptiondisplaysFlash1orFlash2indicatingwhichphysicalashchipthepaneliscurrentlyusing.Pressanytop
rowSelectkeytodisplaythecurrentashinformation.PresstheCOMMANDkeytoviewthenextoption.
Communication Status
This option tests the individual components of cellular or network communication. The displayed results are
shown below.
Cellular Results:
Successful Display Failure Display
MODEMOPERATING NOMODEMFOUND
IDENTIFIED NO SIM CARD
TOWERDETECTED NOTOWER
REGISTERED NOTREGISTERED
This displays the cellular signal strength of the nearest tower for the SIM card carrier. The ’s
representthesignalstrength0-7.SelectYEStocontinuethroughtheremainingcomponent
tests.SelectNOtostoptestingandreturntotheCOMMSTATUSoption.
Successful Display Failure Display
NOCSUCCESS NOCERROR
COMMPATHGOOD NOACKRECEIVED
Network Results:
Successful Display Failure Display
LINKOK LINKERROR
DHCP OK DHCPERROR
GATEWAYFOUND NOGATEWAY
DESTFOUND NODESTINATION
COMMPATHGOOD NOTCONNECTED
NOACKRECEIVED
Cellular Signal Strength (CELL SIGNAL)
This option provides a way to test the cellular signal strength of the nearest tower for
theSIMcardcarrier.PressanytoprowSelectkeytodisplaycellsignalstrength.TheX’s
representthenumericalvalueofthecellsignalstrengthin-dBm.Thesrepresentthe
signalstrength0-7.
Activate Cell
Tobeginthecellularactivationfora463Cor464-263CInterfaceModule,verifythatthemodulehasbeen
activatedforthepanelusingRemoteLink.Atthekeypad,pressanytoprowSelectkeywhenACTIVATE CELL is
displayed. When the SURE NO YES?conrmationmenuappearspresstheSelectkeybeneathYEStocompletethe
cellular activation.
Note: Thisoptiononlydisplaysifa463Cor464-263CInterfaceModuleisattachedtothepanel.
Successful Display Failure Display
CELLACTIVATED NOTACTIVATED
Email Status
TheEmailStatusmenutestseachcomponentofthepanel’se-mailcommunication.Thetestproceedsuntilthe
rst component failure or until all components have been tested with positive results. The test screen displays
after each component and displays for two seconds or until the CMD key has been pressed. The displayed results
are shown below.
Email Results:
Successful Display Failure Display Successful Display Failure Display
EMAILENABLED EMAILDISABLED FROMADDRSENT FROMADDRFAILED
LINKOK LINKERROR DESTADDRSENT DESTADDRFAILED
SMTPSERVEROK INVALIDSERVER DATAMODESENT DATAMODEFAILED
DESTADDRESSOK DESTADDRFAILED MESSAGESENT MSGSENDFAILED
CONNECTING CANNOTCONNECT DISCONNECTED DISCONNECTFAIL
AUTHMODESENT AUTHMODEFAILED EMAILSUCCESS
PASSWORDSENT
BADPASSWORD(orUSERNAME)
SIGNAL: ▐▐▐▐▐▐▐
CONTINUE? NO YES
-XX dBm
SIGNAL:
▐▐▐▐▐▐▐
Vista de pagina 66