Digital Monitoring Products XR100 Series Programming Guide
50
Zone InformatIon
TRANSMTR CONTACT
1 2 3 4
Thisoptiondisplayswhenprogrammingthe1114WirelessFour-ZoneExpander
with four input contacts. The same serial number is used for all four contacts.
Select the contact number to program. When using the contacts, you must use
consecutive zone numbers. Default is Contact 1.
Forexample,useserialnumber08345678toprogramContact1forZone561,
Contact2forZone562,Contact3forzone563,andContact4forzone564.
A tamper on the 1114 is transmitted as the zone number assigned to Contact 1.
ALREADY IN USE
ZONE NUMBER: XXX
This message displays when the Contact is already programmed for another
zone. The programmed zone number displays.
ZONE INFORMATION
NORM OPN NO YES
ThisoptiononlydisplayswhenEXTisselectedastheContacttype.Forexternal
devicesconnectedtothe1101or1103terminalblock,selectNOtouse
normallyclosed(N/C)contacts.SelectYEStousenormallyopen(N/O)contacts.
Default is NO.
Note:ForULlistedinstallations,setNormallyOpentoNO.
18.10.3
TRANSMITTER
SUPRVSN TIME: 240
Supervision Time
Press any top row key to select the supervision time required for the wireless
zone.PressCOMMANDtoacceptthedefaulttime.Defaultis240minutes.
SELECT MINUTES:
0 3 60 240
Press the Select key under the required number of minutes. The transmitter
must check in at least once during this time or a missing condition is indicated
for that zone. 1100 Series transmitters automatically checkin based on the
supervision time selected for the wireless zone, no additional programming
is needed. If two zones share the same transmitter, the last programmed
supervisiontimeisstoredasthesupervisiontimeforbothzones.Zero(0)
indicates an unsupervised transmitter.
The3minutesupervisiontimeisonlyavailableforzonetypesofFire(FI),Fire
Verify(FV),andSupervisory(SV).
Note: When the panel is reset or a receiver is installed or powered down and
powered up, the supervision timer restarts for all wireless zones.
18.10.4
LED OPERATION
NO YES
LED Operation
SelectYEStoturnonan1142Hold-uptransmitterLEDduringPanicor
Emergencyoperation.SelectNOtoturntheLEDoffduringPanicorEmergency
operation.TheLEDalwaysoperateswhenthetransmittercaseisopenandthe
tamperisfaulted.DefaultisYES.
Note:ForULlistedholdupinstallations,setLEDOperationtoNO.
18.10.5
DISARM DISABLE
NO YES
Disarm/Disable
SelectYEStodisablethezonetrippedmessagefroman1103UniversalTransmitter
(Version107orhighersoftware)or1126/1127PIRsduringthedisarmedperiod.
When disarmed, the transmitter or PIR only sends supervision, tamper, and low
battery messages to extend transmitter battery life. For 1103Transmitters,a zone
tripped message is sentifthezoneremainstrippedfor20seconds.SelectNOto
always send zone tripped messages in addition to supervision, tamper, and low
battery.DefaultisYES.
18.10.6
WIRELESS PIR
PULSE COUNT: 4
PIR Pulse Count
Selectthenumberofinfraredpulses(2or4)the1126or1127PIRshouldsense
before sending a short message to the 1100X Series Receiver. Default is 4.
18.10.7
WIRELESS PIR
SENSITIVITY:LOW
PIR Sensitivity
Selectthesensitivitysettingforthe1126or1127PIR.SelectingLOWsets
thePIRtooperateat75%sensitivityforinstallationsinharshenvironments.
SelectingHIGHsetsthePIRtomaximumsensitivity.DefaultisLOW.
18.10.8
NEXT ZONE NO YES
Next Zone
SelectYEStoreturntotheZONENO:-optiontoprogramanewzone.SelectNO
to display the Alarm Action option.
ZONE INFORMATION
WIRELESS? NO YES