XR100 Series Programming Guide Digital Monitoring Products
49
Zone InformatIon
18.9
NEXT ZN? NO YES
Next Zone
SelectYEStoterminatezoneprogramming.ThedisplayreturnstoZoneNumber,
allowing you to enter a new zone number. Select NO to make alter ations to the
AlarmActionforazone.AlarmActionisdenedbeginningwithsection15.12.
Toprogramzonesforwirelessoperation,selectNOattheNEXTZONE-NOYES
option.TheWIRELESSNOYESoptiondisplays.Ifthezoneyouareprogramming
isintendedforwirelessdevices,selectYES.SelectNOtocontinueprogramming
non-wirelesszonesinthe500to599range.
•Zones400to449canbeprogrammedfor1100SeriesKeyFobs.
•Zones500through599canbeprogrammedforDMPWireless.
DMP Wireless
For a DMP 1100X Wireless Receiver settheHouseCodeto1-50.SeeHouseCodeprogramminginSystem
Options.Zones500through599canbeprogrammedasWirelesszones.SettheXR100SeriespanelJ23
jumpertoXtoenableDMPWirelessoperation.Afterpower-up,brieyresetthepanelusingtheJ16jumper
toactivateWirelessoperation.RefertotheXR100SeriesInstallationGuide(LT-0899).
For an 1100 Series Key Fob see section 15.11.
NOTE: All wireless programming is stored in the XR100 Series panel. The 1100X Wireless Receiver obtains
the necessary programming information from the panel each time the receiver powers up, when the
programmer STOP routine is selected or the panel is reset. The receiver memory refresh takes up to 10
secondstocompletedependingonthenumberofwirelesszonesprogrammedandtheRedLEDremainson
during this time. Normal receiver operation is inhibited during the memory refresh period.
18.10 Wireless
SelectYEStoprogramthiszoneasaDMPwirelesszone.Youmustprogramthe
wireless House Code prior to adding DMP wireless zones to the system. See House
Code programming in System Options. Default is NO.
18.10.1
TRANSMITTER
SERIAL#: XXXXXXXX
Serial Number Entry
Entertheeight-digitserialnumberfoundonthewirelessdevice.
ALREADY IN USE
ZONE NUMBER: XXX
This option displays when the serial number is already programmed for another
zone. The programmed zone number displays.
18.10.2
TRANSMITTER
CONTACT:XXXXXXXX
Contact
Thisoptiondisplaysiftheserialnumberenteredisforan1101or1103Universal
Transmitteror1114WirelessFour-ZoneExpander.Pressanytoprowkeyto
select the contact.
TRANSMTR CONTACT
INT EXT
Thisoptiondisplayswhenprogrammingan1101or1103Transmitter.SelectINT
tousetheinternalreedswitchcontacts.SelectEXTtoconnectanexternal
devicetothe1101or1103terminalblock.DefaultisINTERNAL.
ByallowingbothoftheModel1101or1103transmittercontacts(INTand
EXT)tobeusedatthesametime,twozonesmaybeprogrammedfromone
transmitter. When using both contacts, you must use consecutive zone numbers.
Zones531and532orzones590and591areacceptablezoneassignments.
Forexample,programtransmitterserialnumber01345678asZone521with
anINTcontacttypeandZone522withanEXTcontacttype.Thesameserial
number is used for both zones.
Note:Whenusingthe1103UniversalTransmitterinaULlistedCommercial
Burglary installation, the external contact cannot be used.
ZONE INFORMATION
WIRELESS? NO YES