SyStem OptiOnS
9.14
USER LANGUAGE
User Menu and Status List Language
PresstheCOMMANDkeytoselectUserlanguage.
PRI LANG: ENGLSH
Thecurrentprimaryuserlanguagedisplays.ThedefaultlanguageisEnglish.Pressa
SelectkeytochangetheprimaryUserlanguage.
ENG SPN FRN
Select the primary user language.
ENG=English(ENGLISH)
SPN=Spanish(ESPANOL)
FRN=French(FRANCAIS)
SEC LANG: NONE
The current secondary user language displays. Selecting a secondary user language
allowstheusertoviewtheUserMenuandStatusListtextinEnglish,Spanish,or
French.WhentheUserMenuisaccessed,theuserispromptedtochoosethedisplay
language.StatusListtextdisplaysintheselectedlanguageuntilanotherlanguageis
chosen.IfSECLANG:issettoNONE,theoptiontochoosealanguagedoesnotdisplay.
To select a secondary language, press the Select key below the language. Default is
NONE.
Forexample,whenSpanishisselectedatakeypad,theUserMenuandStatusListtext
display in Spanish at that keypad. When the user later accesses the keypad, pressing
theCOMMANDkeyoncedisplaystheoptionforEnglish,Spanish,orFrench.Pressingthe
COMMANDkeyagaincontinuestodisplaytheStatusListtextinSpanish.Lateron,if
EnglishorFrenchisselectedatthat keypad,theUserMenuandStatusListtextdisplay
in the selected language at that keypad.
NONE ENG SPN FRN
Select the secondary user language.
NONE=Nosecondarylanguageoptionsaredisplayed
ENG=English(ENGLISH)
SPN=Spanish(ESPANOL)
FRN=French(FRANCAIS)
9.15
BYPASS LIMIT 0
Bypass Limit
Enterthemaximumnumberofzones(0to8)thatcanbebypassedinanysinglearea
whenthatareaisbeingarmedatakeypad.Ifmorezonesthanthelimitareinanon-
normal state or already bypassed at arming, arming does not occur and Arming Stopped
displays. The Bypass limit does not affect auto arming, keyswitch arming, or remote
arming.Entering0(zero)allowsnolimit.Defaultis0(zero).
9.16
WIRELESS
HOUSE CODE: 0
House Code
When using a DMP wireless system, enter a house code between 1 and 50. When using
FASerieswirelessenter99.SeeWirelessprogramminginZoneInformation.Defaultis0
indicating no wireless system is being used.
TheDMPhousecodeidentiesthepanel,DMPreceiver,andDMPtransmittersto
each other. When operating, the DMP receiver listens for transmissions that have the
programmed house code and transmitter serial number.
Note:TheexibilityofDMPtwo-waywirelessoperationallowsanexistinghousecode
to be changed in the panel at any time. The transmitters may take up to two minutes
to learn the new house code and continue operation.
Note: When any wireless zone programming is changed in the panel, wireless receiver
zone programming is updated. At that point, all wireless zones display as normal for
approximately 1 minute, regardless of the actual state of the zone.
9.17
DETECT WIRELESS
JAMMING: NO YES
Detect Wireless Jamming
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system(1-50).Whenenabledandthewirelessreceiverdetectsjamming,atroubleor
alarmmessagedisplaysintheStatusListandissenttothecentralstationreceiver.
SelectYEStoenablejammingmessagestodisplayintheStatusList.SelectNOto
disable jamming messages. Default is NO.
9.18 Wireless Audible Annunciation
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system(1-50).Pressanytoprowkeytoselectthekeypadbuzzerannunciationmethod
for wireless low battery and missing messages. Select ANY to enable annunciation
anytime. Select DAY to enable annunciation except during sleeping hours
(9PMto9AM).SelectMIN(minimum)toannunciateonlyFireandFireVerifyzones
duringdaytimehours(9AMto9PM).DefaultisDAY.
WLS AUDIBLE: DAY
WIRELESS AUDIBLE
ANY DAY MIN