Digital Monitoring Products XR100 Series Programming Guide
48
Zone InformatIon
18.7
ARM/DIS AREAS
Arming Zone Area Assignment
InanAreaorHome/Sleep/AwaywithGuestsystem,ifthezonehasbeen
programmedasanArmingType(AR),entertheareasthatthezonecontrols.
When the zone changes from normal to shorted, the programmed areas toggle
between the armed or disarmed condition using the Style programming below.
When restored to normal, no action occurs. When the zone is opened from a normal
(disarmed)state,atroubleisreported.Whenopenedfromashorted(armed)state,
analarmisreportedandthezoneisdisableduntilyoudisarmthearea(s)fromeither
akeypadorRemoteLink™computer.
Tovisuallyindicatethearmedstateofthearea(s),youcanassignanArmedOutput
toindividualareasanduseremoteLEDsatthekeyswitch.TheLEDturnsonoroff
toindicatetotheuserthearmedstateofthearea(s).
ARM AREAS: PERIM
InanAll/PerimeterorHome/Sleep/Awaysystem,thisoptionspeciestheareas
tobearmedbytheArmingTypezone.ForAll/Perimetersystems,choosePERIMor
ALL,forHome/Sleep/AwayorHome/Awaysystems,chooseHOME,SLEEP,orAWAY.
PERIM ALL
Perimeter/All-SpecifywhetherthearmingzonearmsjustthePerimeter(PERIM)or
thePerimeterandInteriorareas(ALL)forAll/Perimetersystems.Whendisarming,
all areas are disarmed.
HOME SLEEP AWAY
Home/Sleep/Away-SpecifywhetherthearmingzonearmsthePerimeter(HOME),
thePerimeterandInterior(SLEEP),orallthreeareas(AWAY).Whendisarming,all
areas are disarmed.
Arming Zone Operation
IfanybadzonesarepresentwhentheArmingzoneisshorted,theLEDdelays
lightingfor5seconds.Ifduringthe5-seconddelaytheArmingzoneisshorted
again no arming takes place. If 5 seconds expire without the zone shorting again
or restoring to normal, the areas arm and bad zones are force armed. To allow bad
zonestobeforcearmed,theAnyBypassoptionmustbesettoYES.IfAnyBypass
optionissettoNO,armingdoesnotoccur.SeetheAreaInformation-AnyBypass
section. A priority zone cannot be force armed.
18.8
STYLE:
Style
Thisoptionspeciesthestyleforthearming/disarmingoperation.Thedefault
styleisTGL(toggle).PressanySelectkeytodisplaytheSTYLEoptions.Toview
more style options press the COMMAND key.
TGL ARM DIS STEP
TGL (Toggle) - When the zone changes from normal to shorted, the programmed
areas toggle between the armed or disarmed condition. When restored to normal,
noactionoccurs.Whenthezoneopensfromanormal(disarmed)state,atroubleis
reported.Whenopenedfromashorted(armed)state,analarmisreportedandthe
zoneisdisableduntilyoudisarmthearea(s)fromeitherakeypadorRemoteLink.
ARM - When the zone is shorted, the programmed areas are armed. When restored
tonormal,noactionoccurs.Whenthezoneisopenedfromanormal(disarmed)
state,atroubleisreported.Whenopenedfromashorted(armed)state,analarm
is reported.
DIS (Disarm) - When programmed, a short disarms the programmed areas. When
restored to normal, no action occurs. When the zone is opened from a normal
(disarmed)state,atroubleisreported.
STEP - A short arms the areas and beeps the keypads once. A normal condition
causes no action. An open condition disarms the programmed areas and beep the
keypads for one second.
Note: This arming style is designed for wireless arming pendants. When using a
arming/disarmingkeyswitchlocatethekeyswitchwithintheprotectedarea.
MNT
MNT (Maintain) - When the zone is shorted, the programmed areas are armed.
When restored to normal, the programmed areas are disarmed and any alarm bells
aresilenced.Whenthezoneisopenedfromanormal(disarmed)state,atrouble
isreported.Ifopenedfromashorted(armed)state,analarmisreportedandthe
zoneisdisableduntilyoudisarmthearea(s)fromeitherakeypadorRemoteLink.