Digital Monitoring Products Canadian XR100 Manual de instrucciones Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 78
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
Digital Monitoring Products XR100 Series Programming Guide
10
CommuniCation
3.14
RECEIVER PORT -
Receiver Port
2001
Enterthereceiverportnumber.Validrangeis1to65,535.Defaultis2001.
3.15
FIRST PHONE NO.
First Telephone Number
This option displays only if the Communication Type is DD or CID.
Thisistherstnumberthepaneldialswhensendingreportstothereceiver.Phone
numberscanhavetwolinesof16characterseachtoequalupto32characters.
EnterPtoprogramathree-secondpauseinthedialingsequence.ThePcharacter
countsaspartofthe32allowablecharacters.
EnterRastherstcharacterforrotary(pulse)phonefunction.TheRcharacter
countsaspartofthe32allowablecharacters.
Call Waiting: You can place the “*70P”(Star,Seven,Zero,Pause)inthe
telephonenumberrstpositiontocancelCallWaiting.Forexample,programNET
withsecondlineDDandphonenumber*70P555-1212,andyouhaveNETwithCall
Waiting cancelled on the second line.
Caution:Acallwaitingcancelprogrammedonanon-callwaitingtelephoneline
would prevent communication to the central station.
3.16
SECOND PHONE NO.
Second Telephone Number
Thepaneldialsthesecondnumberwhentwosuccessivetriesusingtherstnumber
fail. If the panel cannot reach the receiver after two attempts using the second
number,itreturnstotherstnumberandmakestwoadditionalattempts.Atotal
oftendialingattemptsaremadeusingtherstandsecondphonenumbers.
Eachnumbercanbeupto32charactersinlengthincludinganyPorRcharacters
entered for pause or rotary connections or call waiting cancel option.
Should all ten attempts fail, the panel continues to attempt sending the message
using the next programmed path. If all programmed communication paths fail, the
panel clears the communication buffer and makes one communication attempt
eachhourtosendaTRANSMITFAILED(S87)reporttothereceiver.AccesstheUser
MenuDisplayEventsfeaturetoviewthereportinformationnotsenttothereceiver
ordownloadthereportwithDMPRemoteLink™software.
3.17
ADVANCED? NO YES
Advanced Programming
Select Yes to enter the Advanced Programming menu for the communication path
currently being programmed.
3.18 First GPRS APN
EntertherstAPN(AccessPointName).Thisallowsanaccesspointforcellular
communication and is used to connect to a DNS network. The APN may contain two
linesof16characterstoequal32characters.DefaultissettoSECURECOM400.
Note:Thisoptionisnotusedwhena463CCDMAor464-263CCellular
Communicator is used for communication.
Second GPRS APN
EnterthesecondAPN(AccessPointName).Thisworksasabackupincasetherst
APNfails.TheAPNmaycontaintwolinesof16characterstoequal32characters.
DefaultissettoSECURECOM400.
Note:Thisoptionisnotusedwhena463CCDMAor464-263CCellular
Communicator is used for communication.
3.19
FAIL TEST HRS: 0
Fail Test Hours
This option sets the frequency for a Backup or Adaptive path to send a test report
when the closest previous path fails within its path group.
For example, if a backup path is programmed to send a weekly test report and the
FailTestFrequencyissetto2hours,whenthepreviouspathfailswithinitsgroup,
thebackuppathstartssendingatestevery2hoursuntilthepreviouspathrestores.
If Fail Test Frequency is set to 0, test reports are sent only according to Test Report
programming.Rangeis0to24hours.Defaultis0.
SECURECOM400
-
SECOND GPRS APN
SECURECOM400
-
FIRST GPRS APN
Vista de pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 77 78

Comentarios a estos manuales

Sin comentarios