System Link User’s Guide 87
Default Profiles Table
Number
Menu Privilege
1 2 3 4 5 6 7 8 9 10 11-98 99
ARM/DIS NO YES Arm and Disarm
No Yes Yes Yes Yes Yes Yes Yes Yes No No Yes
ALM SLNC NO YES Alarm Silence
No Yes Yes Yes Yes Yes Yes Yes Yes No No Yes
SNSR RST NO YES Sensor Reset
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes
DOOR ACS NO YES Door Access
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes
ARM AREA NO YES Armed Areas
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes
OUTPUTS NO YES Outputs ON/OFF
No No No No Yes Yes Yes Yes Yes No No Yes
ZN STATS NO YES Zone Status
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes
BYPAS ZN NO YES Bypass Zones
No No No No No Yes Yes Yes Yes No No Yes
ZONE MON NO YES Zone Monitor
No No No Yes Yes Yes Yes Yes Yes No No Yes
SYS STAT NO YES System Status
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes
SYS TEST NO YES System Test
No No No Yes Yes No Yes Yes Yes No No Yes
PROFILES NO YES User Profiles
No No No No No No No No Yes No No Yes
USR CODE NO YES User Codes
No No No No No No No No Yes No No Yes
SCHEDULS NO YES Schedules
No No No No No No Yes Yes Yes No No Yes
TIME NO YES Time
No No No No No No No Yes Yes No No Yes
DIS EVNT NO YES Display Events
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes
SERV REQ NO YES Service Request
No No No No No No No Yes Yes No No Yes
FIRE DRIL NO YES Fire Drill
No No No No No No No Yes Yes No No Yes
EXTEND NO YES Extend Schedules
No No No No No Yes Yes Yes Yes No No Yes
TEMP CODE NO YES Temporary User Code
No No No No No No No No No No No No
ANTI PASS NO YES Anti-passback
No No No No No No No No No No No No
EASY ARM /
DISARM
NO YES Arm/Disarm
No No No No No No No No No No No No
1234 ANYTIME ___ ANYTIME Shift/Time Access
1234 1234 Any Any Any Any Any Any Any Any Any Any
RE ARM DLY*
0-250
Re-Arm Delay
No No No No No No Yes Yes Yes No No Yes
SEC LANGUAGE
NO YES Language
No No No No No No No No No No No No
* This option is only available on XR500 Series and XR2500F panels version 106 or higher and XR100 Series panels.
Note: For XR500 and XR100 Series panels configured for All/Perimeter or Home/Sleep/Away use the default Profiles 1 through 10. For
Home/Sleep/Away with Guest systems use the default profiles 1 through 9 for the main house system, default profiles 11-19 for the Guest 1
house system, and default profiles 21-29 for the Guest 2 house system.
User Code Authority Levels
Menu Options
1 2 3 4 5 6 7 8 9
Sensor Reset
* *
Armed Areas
* *
Zone Status
* *
System Status
* *
Display Events
* *
Door Access
* *
Arm and Disarm
**
Alarm Silence
*
System Test
Zone Monitor
Outputs On/Off
Extend
Bypass Zones
Schedules
Service Request
Fire Drill
Set Time
User Codes
* These functions can only be accessed during certain schedules.
** Arming allowed anytime. Disarming allowed outside of a schedule, but an Unauthorized Entry report is sent to
the central station.