System Link User’s Guide
8
Quick Connect
Connecting Directly to a Panel through a 462N Interface Card or
XR500 Series Serial Port
To configure System Link to connect directly to a panel, follow the steps below:
1. Select the desired panel in File > Panel Information.
2. In the Connection Information group box, select Direct from the drop-down
menu in the Type field.
3. Select the COM Port to which the panel is connected.
4. Select the Baud Rate of the COM Port.
Note: You only need to complete these steps one time. On further connections simply
select the panel and then Connect as explained below.
After you have entered all the Connection Information, open the panel by clicking OK.
Then go to Panel > Connect and click the Connect button. You are now connected to
the panel.
Connecting to a Panel using an SCS-1, SCS-1R, or SCS-105 Receiver
To configure System Link to connect to a panel through an SCS-1, SCS-1R, or SCS-105
Receiver using a dial-up connection, follow the steps below:
1. Select the desired panel in File > Panel Information.
2. In the Connection Information group box, select SCS-1/SCS-105 from the
drop-down menu in the Type field.
3. Enter the Remote Key.
4. Enter the phone number of the panel.
5. Select Yes from the drop-down menu in the Dial field.
Note: You only need to complete these steps one time. On further connections simply
select the panel and then Connect as explained below.
After you have entered all the Connection Information, open the panel by clicking OK.
Then go to Panel > Connect and click the Connect button. You are now connected to
the panel.