System Link User’s Guide 67
Profiles
The Profiles window allows you
to add, delete, or change user
profiles. A profile defines the
authority of each user code in
the system. The Profiles window
for XR500 Series and XR2500F,
and XR100 Series panels is
displayed to the right. The
Profiles window for XR200-485
and XR200-485B panels is
displayed below to the right.
Profile
: Enter a number to
assign to the profile. Each
profile may be assigned a unique number from 1 to 99.
Note: On XR500 and XR100 Series panels Profiles cannot be changed via keypad for
All/Perimeter or Home/Sleep/ Away operation. Use the default Profiles 1 to 10.
Name
: Enter a name to assign to the profile you are programming. Each profile may be
assigned a 32-character name.
Arm / Disarm Areas
: Enter the number for the areas that you want to authorize this
profile to arm and disarm. Beginning with XR500 Series and XR2500F version 110 and XR100
Series, you can specify separate arm and disarm authority for a profile.
Each profile may be assigned specific areas of the burglary part of the system for arming
and disarming. When profiles 1 to 98 are created, no areas are assigned by default. By
default, profile 99 is assigned authority to all areas.
To enter an area number, click once in the field to select it and type the number key for
the desired area. The number appears in the field. To remove an area, type the number
for that area in the Arm / Disarm Areas field.
Profiles menu is
available on:
XR100
XR100N
XR500
XR500N
XR500E