XR100 Series Canadian Installation Guide Digital Monitoring Products
23
ComplianCe
False Alarm Reduction Programmable Options (continued)
24.2 Call Waiting (ANSI/SIA CP-01-2010)
TheCallWaitingdefaultsettingisdisabled.TocanceltheCallWaitingfeature,program*(star)70P(pause),thestandard
telephonecodeprexthatcancelscallwaiting,intothetelephonenumberstring.CancelCallWaitingfortelephonelines
thathaveCallWaitingoperationalonthetelephoneline.SeetheXR100SeriesCanadianProgrammingGuide(LT-0896CAN).
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent communication to
the central station.
24.3 Occupied Premise (ANSI/SIA CP-01-2010)
Whenonlytwoareasareused,andareaoneisnamedPerimeter,andareatwoisnamedInterior,andnoexittypezone
transition occurs during the exit delay because the premise continues to be occupied, the Interior area will automatically
disarm at the end of the exit delay.
24.4 Entry Delay (ANSI/SIA CP-01-2010)
OnlyuseEntryDelay1.DonotuseEntryDelay2,3,or4.SeetheXR100SeriesCanadianProgrammingGuide
(LT-0896CAN).
24.5 Minimum Installation Requirements (ANSI/SIA CP-01-2010)
SIA CP-01-2010 minimum system installation requirements include an XR100 Series, a listed local Bell, and off premise
DACT communication to an SCS-1R receiver plus one of the following compatible keypads.
630F Fire Command™ Center
7060, 7063, 7070, or 7073 Thinline™ keypads
7060A, 7063A, 7070A, or 7073A Aqualite™ keypads
7160, 7163, 7170, or 7173 Thinline™ keypads