Digital Monitoring Products Canadian XR100 Guía de instalación Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
XR100 Series Canadian Installation Guide Digital Monitoring Products
21
ComplianCe
ULC S559-04 Specications
Equipment for Fire Signal Receiving Centers and Systems
22.1 For Fire Communicator Applications
Forrecommunicatorapplications,communicationtotheresignalreceivingcenterisprovidedforInternet,Intranet,
LANorWANnetworkswhenconguredasaNETorCELLcommunicatingsystemusingtheXR100Seriespanel.Seewiring
diagraminsection25.4foradditionalinformation.ProgramoneofthefollowingoptionsinpanelCommunication:
Path 1 Type NET or CELL Primary with no Backup
Path 1 Programming
Comm Type = NET or CELL Checkin Min = 3
Path Type = Primary Failtime Min = 3
Sub Code = No Send Comm Trbl = Yes
Comm Path Trbl = Yes (Status List Programming)
Path 1 Type NET Primary and Path 2 Type CELL Backup
Path 1 Programming Path 2 Programming
Comm Type = NET Comm Type = CELL
Path Type = Primary Path Type = Backup
Test Rpt = Yes Test Rpt = Yes
Test Freq = 1 Dy Test Freq = 1 Dy
Send Comm Trbl = Yes Send Comm Trbl = Yes
Comm Path Trbl = Yes (Status List Programming)
22.2 Central Station Host Automation
Theresignalreceivingcenter’shostautomationsystemmustrecognizethefollowingsignals:Zone1Alarm=FireAlarm,
Zone2Trouble=FireZoneTrouble,Zone3Trouble=ACTrouble,Zone4Trouble=BatteryTrouble,andZone5Trouble=
GroundFaultTrouble.
Recommendations
23.1 ULC Installation Recommendations
1. In order to give the digital alarm communicator transmitter the ability to disconnect an incoming call to the protected
premises, telephone service should be of the type that provides for timed release disconnect.
2.Networkaccessanddomainaccesspoliciesshallbesettorestrictunauthorizednetworkaccessand“spoong”or
“denialofservice”attacks.
3.SelectInternetServiceProvidersthathaveredundantservers/systems,Back-uppower,RouterswithFirewallenabled
andMethodstoidentifyandprotectagainst“DenialofService”attacks(i.e.via“spoong”).
4.Powerfornetworkequipmentashubs,switches,routers,servers,modems,etc.,shallbebackeduporpoweredby
anun-interruptablepowersupply(UPS),stand-bybatteryorthecontrolunit,capableoffacilitating24hourstandby,
compliantwithClauses16.1.2and16.4.1ofCAN/ULC-S304-06.
5.Wheresuchcannotbefacilitated,thecontrolunitshallsupportback-upcommunicationsforasecondary
communications path, subject to the following:
Low Risk and Medium Risk shall use a dialer as a minimum;
High Risk shall use cellular control channel or long range radio as a minimum; and
VeryHighRiskshallbeequippedwith24hourstandbypower.Note:RefertoTable11ofCAN/ULC-S304-06fortherisk
levels.
6.RefertoCAN/ULC-S302,InstallationandClassicationofBurglarAlarmSystemsforFinancialandCommercialPremises,
SafesandVaults,forrequirementsforasecondarycommunicationspath,where24hourstandbycannotbefacilitatedfor
all communications interface components as routers, hubs, switches and other network components.
7. Products or components of products used in communication channels, which perform communications functions only,
shallcomplywiththerequirementsapplicabletocommunicationsequipmentasspeciedinCAN/CSA-C22.2No.60950-1,
InformationTechnologyEquipment-Safety-Part1:GeneralRequirements.Suchproductsorcomponentsinclude,butare
not limited to:
A Hubs;
B Routers;
C Network interface devices;
D Third party communications service providers;
E Digital subscriber line (DSL) modems; and
F Cable modems