Reset and Tamper Headers
18.1 J16 Reset Header
The reset header is located just above the terminal strip on the right side of the circuit board and is used to reset the
XR100Seriesmicroprocessor.Toresetthepanelwhenrstinstallingthesystem,installtheresetjumperbeforeapplying
power to the panel. After connecting the AC and battery, remove the reset jumper.
To reset the panel while the system is operational, for example, prior to reprogramming, install the reset jumper without
powering down the system. Remove the reset jumper after one or two seconds.
After resetting the panel, begin programming within 30 minutes. If you wait longer than 30 minutes, you must reset the
panel again.
18.2 J4 Tamper Header
TheJ4headerisforusewiththeoptionalDMP306TamperHarness.Theharnessconnectstooneormoretamperswitches
mounted inside the panel enclosure to supervise against unauthorized enclosure opening or removal. Refer to the wiring
diagram on the enclosure door for correct tamper switch wiring.
How the Tamper Works
If the enclosure is opened or removed while one or more of the system areas are armed, a panel tamper alarm is
indicated. If all areas are disarmed, a panel tamper trouble is indicated.
To enable Wireless Keypad
Association operation:
Reset panel 3 times within
12 seconds.
To access the programmer:
Momentarily place the
Reset jumper over both of
the J16 pins to reset the
panel.
J16
Reset
AC
12345678 10 11 12 13 14 15 16 17 18 19
02122232425262728
+B BELL GND SMK GNDRED YEL GRN BLKZ1Z2Z3Z4Z5Z6Z7Z8 Z9+ Z9– Z10+ Z10–AC –B GND GND GNDGND
K6 K7
Output 1Output 2
J3
Phone Line
J10
J22
LX-Bus
Battery
Start
Power
LED
J8
PROG
J4
Tamper
Out1 Out2
Outputs 3-6
J11
3
4
5
6
J2
J1
Ethernet
OVC
Link LED
Activity LED
J23
R
L
X
Figure 10: XR100 Series Canadian Panel Showing the Reset Jumper
Comentarios a estos manuales