17.21 Arm First Area
Select YES to enable this area to operate as an Arm First area. This area is automatically
armed when any non-Arm First area assigned to the same keypad is armed but does not
disarm when other areas become disarmed. Assign areas to keypads using the Display Areas
option in Device Setup programming. You can have multiple Arm First areas in a system and
divide them among keypads if needed. If an Arm First area has faulted zones that cannot
be bypassed, arming stops and the areas are not armed. Correct the problem with the Arm
First area and then begin the arming process again. Default value is NO.
Note: The Arm First automatic arming only occurs when arming from a keypad. Arming
from a zone, schedule, or remotely is not affected and Arm First areas do not automatically
arm.
17.22 Two Man Rule (XR550 with Network or Encryption only)
Select YES to require two user code entries to disarm and/or allow door access to this area.
When a user presents a code to a keypad or reader requesting a door access or disarm,
2ND CODE displays and requires the entry of a different user code with at least the same
authority. The second user code must be entered within 30 seconds.
NO disables the Two Man Rule for this area.
ARM FIRST NO YES
TWO MAN NO YES