15.3 LX-Bus Interface Cards
YoucanaddoneInterfaceCard(Model481,462N,462P,or464-263H)totheXR500SeriesusingJ6InterfaceCard
Connectorlocatedontheboardrightedge.ToaddmorethanoneInterfaceCardinstalla461InterfaceAdaptorCard
usingJ6InterfaceCardConnectorontheboardrightedge.The461AdaptorCardallowsuptoveInterfaceCards
tobeinstalled.Refertothe461InstallationSheet(LT-0736).EachInterfacecardprovidesupto100LX-BusZones.
Refer to the following tables to identify zone locations and numbers relative to J22 operation.
J22 LX-Bus Enabled
(Set J23 to “L”)
AND
One Interface Card
OR
461 Adaptor Card and
Multiple Interface Cards
LX-Bus Zone Numbers LX-Bus Zone Numbers LX-Bus Zone Numbers
1 500-599 2 600-699 2 (A) 600-699
3 (B) 700-799
4(C) 800-899
5 (D) 900-999
J22
LX-Bus
NOT
Enabled
(J23
NOT set
to “L”)
One Interface Card
OR
461 Adaptor Card and
Multiple Interface Cards
LX-Bus Zone Numbers LX-Bus Zone Numbers
1 500-599 1 (A) 500-599
2 (B) 600-699
3 (C) 700-799
4(D) 800-899
5 (E) 900-999
15.4 LX-Bus LEDs
The two LEDs, located near the bottom-right corner of J21 indicate data transmission and receipt. The top LED
ashesgreentoindicatethepanelistransmittingLX-Busdata.ThebottomLEDashesyellowtoindicatethepanel
is receiving LX-Bus data.
15.5 OVC LED
TheOvercurrentLED(OVC)lightsRedwhenthedevicesconnectedtotheKeypadBusandLX-Bus(es)drawmore
current than the panel rating. The OVC is located above Outputs 1 and 2 on the panel and turns a steady Red when
lit.WhentheOVCLEDlightsRed,theLX-Bus(es)andKeypadbusshutdown.
J21 Serial Connector
16.1 Description
Note: Only one connector, J21 or J22 can function at a time. Either use J21 to connect a serial device for PC Log
Reporting,oruseJ22toconnectaDMPWirelessdeviceoranLX-Busdevice.Operationisdeterminedbywhereyou
install the jumper on the J23 6-Pin header. The maximum line impedance is 100 Ohms.
To enable J21 to operate in RS-232 mode, place a jumper on the two pins next to the letter “R” on the J23 6-Pin
headerandbrieyresetthepanelusingtheJ16jumpertoactivatetheselectedoperation.Panelprogrammingusing
Remote Link™ can be set up through a direct connection to a computer. The Serial Connector allows the following
operation options.
XR500 Panel XR500N/XR500E Panel
PC Log Reports PC Log Reports
Remote Link™
Programming
16.2 Computer Connection to J21
Use a straight through RS-232 Serial cable with a DB-9 female connector on one end and a DB-9 male connector on
the other end. Plug the DB-9 male connector end of the cable onto the XR500 Series panel J21 RS-232 connector.
Plug the DB-9 female connector end of the cable onto the DB-9 male connector located at the back of the computer.
Program the XR500 Series panel as needed then disconnect the computer.
16.3 Serial Connector LEDs
The two LEDs, located near the bottom-right corner of J21 indicate data transmission and receipt. The top LED
ashesgreentoindicatethepanelistransmittingserialdata.ThebottomLEDashesyellowtoindicatethepanelis
receiving serial data.
Serial Data Xmit LED
Serial Data Rec(eive) LED
J22
J23
J21
RS-232
R
L
X
DB-9 Female Connector
Figure 9: J21 Serial Connection