XR500 Series Canadian Installation Guide Digital Monitoring Products
7
InstallatIon
5 4 3 2 1
9 8 7 6
G
RS232
J1
Ethernet
J3
Phone
Line
R
L
X
J23
J16
Reset
Outputs 3-6
Out1 Out2
Output 2
Output 1
K7K6
RED
J22
LX-Bus
RED
J10
J8
J4
Tamper
XR500 Series
Canadian Panel
Power
LED
Link LED
Activity LED
OVC
12345678 10 11 12 13 14 15 16 17 18 199202122232425262728
AC +B BELL GND SMK GNDRED YEL GRN BLKZ1Z2Z3Z4Z5Z6Z7Z8 Z9+ Z9– Z10+Z10–AC –B GND GND GNDGND
J6 Expansion Slot
56 VA
Transformer
Mounting for one (1)
Zone Expansion Module.
Battery Shelf
Mounting
Plate
Figure 4: XR500 Series in Model 352X Enclosure and Separate 352S Enclosure with Shelves
4.2 Mounting Keypads and Zone Expansion Modules
DMPLCDkeypadshaveremovablecoversthatallowyoutoeasilymountthekeypadtoawallorotheratsurface
using the screw holes on each corner of the base. Before mounting the base, connect the keypad wire harness leads
to the keypad cable from the panel and to any device wiring run to that location. Then attach the harness to the pin
connector on the PC board, mount the base, and install the keypad cover making sure all of the keys extend through
their respective holes.
For mounting keypads on solid walls, or for applications where conduit is required, use the Model 695 1-1/2” deep or
the Model 696 1/2” deep backboxes.
TheDMP711,712-8,714,715,716,and717modulesareeachcontainedinmoldedplastichousingswithremovable
covers. The base provides you with mounting holes for installing the unit to a wall, switch plate, or other surface.