14 XR150FC/XR550FC User’s Guide System Setup
User Proles
Change User Proles, that dene the authority of each user code
in the system. Several characteristics dene the authority of each
User Prole within the system.
Prole Number - Each prole may be assigned a unique number
from 1 to 99.
Prole Name - Each prole may be assigned a 16-character name.
The Prole Number is the default name.
Arm or Disarm Areas - Each prole may be assigned specic areas
of the system for arming and disarming. When proles 1 to 98 are
created, NO areas are assigned by default. The default for prole
99 is ALL areas assigned. Prole 99 is predened in the system by
the factory.
Access Areas - Each prole may be assigned door access area
assignments. Default for prole 1 to 98 is NO areas assigned.
Default for prole 99 is ALL areas assigned. Prole 99 is predened
at the factory.
Output Group Assignment - Each prole may be assigned an output
group number from 1 to 10. Default for prole 1 to 98 is NO output
group assigned. Default for prole 99 is output group 10. Your
system may by programmed to turn on an output group at certain
keypads when door access occurs.
User Menu Assignments - Each user prole may have any of the
menus assigned to it as shown in the User Prole Record below. The
User Prole Record lists the user menu prole assignments and the
system functions users are allowed to access based on the prole
numbers assigned to their codes.
Always make sure that at least one administrator in your system has
a prole with all authorities and all areas.
User Proles Reference
Menu Display Privilege
ARM NO YES Arm
DIS NO YES Disarm
ALM SLNC NO YES Alarm Silence
SNSR RST NO YES Sensor Reset
LOCKDOWN NO YES Lockdown
DOOR LOCK/UNLOCK NO YES Door Lock/Unlock
DOOR ACS NO YES Door Access
ARM AREA NO YES Armed Areas
OUTPUTS NO YES Outputs ON/OFF
FAVORITES F01- F20 Z-Wave Favorites
ZN STATS NO YES Zone Status
BYPAS ZN NO YES Bypass Zones
ZONE MON NO YES Zone Monitor
SYS STAT NO YES System Status
SYS TEST NO YES System Test
PROFILES NO YES User Proles
USR CODE NO YES User Codes
SCHEDULS NO YES Schedules
TIME NO YES Time
DIS EVNT NO YES Display Events
SERV REQ NO YES Service Request
FIRE DRILL NO YES Fire Drill
EXTEND NO YES Extend Schedules
TEMP CODE NO YES Temporary User Code
ANTI PASS NO YES Anti-Passback
ACCESS SCHEDULES Sch. 1-99 Allow: Shift/Time Access
RE ARM DLY 0 – 720 Re-Arm Delay
SEC LANGUAGE NO YES Preferred Language