Digital Monitoring Products, Inc.
1912XR Programming
Page 2
1-INTRODUCTION
1.2 Getting Started continued
Accessing the Programmer
To access the Programmer function of the 1912XR:
1. Install the reset jumper across the two J16 reset pins for two seconds. See Figure 1.
2. Remove the reset jumper and place it over just one pin for future use.
3. Enter the code 6653 (PROG) into any Security Command keypad.
4. Press COMMAND.
5. The keypad displays: PROGRAMMER.
You are now ready to start programming the 1912XR panel. Pressing the COMMAND key scrolls
you through the programming functions listed in section 1.3. Each of these functions are described
in detail in sections 2 to 15 of this manual.
1.3 Programmer Operation
Once at the PROGRAMMER display, pressing the COMMAND key scrolls you through the
programming menu. There are 14 programming sections to choose from:
Menu Item Section in this manual
Initialization 2
Communication 3
Device Setup 4
Remote Options 5
System Reports 6
System Options 7
Output Options 8
Menu Display 9
Status List 10
Printer Reports 11
Area Information 12
Loop Information 13
Stop 14
Set Access Code 15
AC BELL
AC
1
2
34 56 789
10
11
12
13
14 15
16
17 18 19
GND
RED YEL GRN BLKB + B - SMK L5+ L5- L1 L2 L3 L4GNDGND
1k Ω
3.3k Ω Resistor
DMP Model 309
1k Ω
1k Ω
Battery Only Restart
J16
Command Processor Reset
1k Ω
Cold Water Pipe
Earth Ground
Figure 1: Installing the reset jumper on J16
J16