Digital Monitoring Products XRSuper6/XR20/XR40 Installation Guide
4
IntRoduCtIon
3.4 Accessory Devices continued
1161 Residential Smoke Detector Residential smoke detector with sounder.
1162 Residential Smoke Detector Residential smoke/heat detector with sounder and xed rate-of-rise heat detector
Accessory Modules and Keypads
iCOMsl Network Alarm Router Allows network connection for alarm communication
* ePAD™ Virtual Keypads Allows users to control the security system from any computer in the world using the
Internet.
LCD keypads Allows you to control the panel from various remote locations. Connect up to four keypads
on XRSuper6 and XR20, and up to eight keypads on the XR40. Model 690/690F, 790/790F,
693/793 Security Command™ keypads, 7060/7160, 7063/7163, 7070/7170, 7073/7173
Thinline™ keypads, 7060A, 7063A, 7070A, 7073A Aqualite™ keypads, 7360, 7363 Thinline Icon
Series keypads, or 7760 Clear Touch™ keypad to the keypad bus using terminals 7, 8, 9, and
10.
* These devices have not been investigated by a Nationally Recognized Testing Laboratory (NRTL).
3.5 XRSuper6/XR20/XR40 Wiring Diagram
J4
RED
PROG
J8
XRSuper6/XR20/XR40
Command
Processor™ Panel
J16
Command
Processor Reset
J7
RJ SUP
AC
1
2
3
4567
8
10
11 12 13 14
15
16 17 18
19
9
20
21
22 23
24
25 26
+B
BELL
GND
SMK
RED
YEL
GRN
BLK
Z1
Z2 Z3 Z4
Z5
Z6
Z7
Z8 Z9
Z10-
AC
-B
GND
GND
GND
GND
Z10+
ProgrammerHeaderJ8
Use DMP Model 330 Harness
RJ Cable Monitor
J7. Use DMP Model
306 Harness
Phone Jack Connector
16 to 18
gaugewire
Maximum AC
Wire distance –
16gaugewire:70feet
18gaugewire:40feet
RED
BLACK
Cold Water Pipe
Earth Ground
s
s
s
s
ACWiringmustbeinconduitandexitout
the left side of the enclosure.
Wiringonterminals5through26mustexit
rightandmaintaina1/4"separationfrom
theACandbatterypositivewiring.
USE MARKING
HouseholdFireandBurglaryWarningSystem
Control Unit.
CommercialBurglarandHoldupAlarmSystem
Control Unit.
NFPA 72
This equipment should be installed in accordance with Chapter 2
of the National Fire Alarm Code, ANSI/NFPA72-1996,(National
Fire Protection Association, Batterymarch Park, Quincy, MA
02269).Printedinformationdescribingproperinstallation,
operation,testing,maintenance,evacuationplanning,andrepair
service is to be provided with this equipment. Warning:Owner’s
instruction notice, not to be removed by anyone except occupant.
HOUSEHOLD FIRE WIRING
Recognizedlimitedenergycablemustbe
usedforconnectionofallinitiating,
indicating,andsupplementarydevices.
POWER LIMITED
All panel circuits comply with the
requirements for inherent power limitation
and are Class 2.
AUX — Up to 500mA auxiliary current
at 10.4 to 13.2 VDC from Terminal 7.
TYPES OF SERVICE
Whenusedwiththe350AorEnclosure:
Suitable for Local and Police Connect
Mercantile Premises with Standard Line
Security, Local and Police Connect
Mercantile
Safe and Vault with Standard Line
Security,
DACT Central Station and proprietary.
Suitable for Household Fire and
HouseholdBurglary. Test weekly.
Suitable for Standard Line
Network Security.
SIA CP-01-2000 minimum system is
XRSuper6, XR20, XR40
UL listed local Bell,
and off premise DACT
communication to an
SCS-1R receiver plus
ANSI/SIA CP-01-2000
classifiedcompatible
DMP keypads as
indicated in the
installationguide.
Listed Resistors
1.0k Ohm -
DMP Model 311
3.3k Ohm -
DMP Model 309
Pluginto
120 VAC
60 Hz
outlet not
controlled
by switch.
J11
U11
EPROM
Socket
1
2
3
4
Zone 10 compatibility
identifier:A
Maximum operating
range:
8.8 VDC - 14.2 VDC.
See the panel
Installation Guide
(LT-0624)foralist
of approved 2-wire
smoke detectors.
DMP Transformers
Model 320 – 16.5 VAC 40 VA
Class 2 wire-in.
Model 321 – 16.5 VAC 40 VA
Class2plug-in.
Smoke Output: — 100mA at
10.4 to 13.2 VDC Terminal 11.
Verification
Zone
10
Control Unit
Delay
13.6 sec.
Smoke
Model
______
Detector
Delay
____sec.
Heat detectors, manual pull stations, or any other
shortingdevice.Unlimitednumberofunits.
Bell — 10.4 - 13.2 VDC
Totalcurrent:1.5Ampsmax.w/40VA
1K Ohm EOL
on each zone
3.3K Ohm EOLSwitched
Voltage
Output
Zone 10Keypad
Bus
SmokeZones 1 to 9 (1-5 on XRSuper6)Bell
Household System
Analarmsoundingdevicemust
be installed indoors so that it is
clearlyheardinallsleepingareas.
Secondary Power Supply
1.2Ampsmaximumchargingcurrent.Useonly
12VDCrechargeablebatteries.DMPModel367.
Replace every 3 to 5 years.
Minimumvoltageon
Auxiliary output to
process Sensor trips
is 10.2 VDC.
Terminals 5-20 are Power Limited.
ForWirelessDevices,ControlUnitdelayis0(zero).
Figure 1: System Wiring Diagram