7160-14
Model 7160 HD/SD/ASI/310 Protection DA
CONTROL LOCAL REMOTE DEFAULT USER LEVEL
Auto Reset On On
O
On Admin
Reset Time 15 seconds 0 - 60 seconds 15 seconds Admin
TRS Test Switch 1:
On
O
O
Lenient
Strict
Lenient Admin
ASI Test Switch 2:
O
Simple
Pgm Specic
PID Specic
O
Simple
Pgm Specic
PID Specic
O Admin
Audio Detect Switch 3:
On
O
On
O
On Admin
Black Detect Switch 4:
On
O
On
O
On Admin
Freeze Test/Mode Switch 5:
On
O
O
Clean Source
Noisy Source
O Admin
Window Big Small
Big
Big Admin
Black Time 3 sec 0 - 300 sec 3 sec Admin
Detect Level 10 IRE 0 - 100 IRE 10 IRE Admin
Black Fraction 5% 0 - 100% 5% Admin
Audio Group Group 1 Group 1
Group 2
Group 3
Group 4
Group 1 Admin
Audio Threshold -20 VU 0VU
-5 VU
-10 VU
-15 VU
-20 VU
-25 VU
-30 VU
-35 VU
-40 VU
-20 VU Admin
Audio Time 3 sec .5 - 300 sec 3 sec Admin
Audio Channel
enable
Enabled
Enabled
Disabled
Disabled
Ch1 enable/disable
Ch2 enable/disable
Ch3 enable/disable
Ch4 enable/disable
Enabled
Enabled
Disabled
Disabled
Admin
Freeze Mode Noisy Source
Clean Source
Noisy Source
Clean Source
Clean Source Admin
Freeze Time 3 sec 0 - 300 sec 3 sec Admin