. Copyright Genelec Oy 4.2003. All data subject to change without prior notice
FIN-74100, Iisalmi, Finland
Email genelec@genelec.com
In the U.S. please contact
Genelec, Inc., 7 Tech Circle
Email genelec.usa@genelec.com
(18 dB/octave) below 19 Hz
Upper bandwidth/LFE cutoff 85 Hz/120 Hz selectable
(sub/main channels) 85 Hz
Midband rejection >400 Hz
Bass roll-off control operating From 0 to –6 dB @ 20 Hz
Phase matching control From 0 to 270° @ 85 Hz
AMPLIFIER SECTION
INPUT SECTION
CROSSOVER SECTION
SYSTEM SPECIFICATIONS
Free field frequency response 19 Hz…85 Hz
Maximum short term sine wave
Maximum peak SPL output with
random pink noise, measured
Self generated noise level in
Harmonic distortion @ 105 dB SPL
at @ 1 m on axis in half space 30 … 85 Hz
Width 1440 mm (56 11/16”)*
* If the subwoofer is flush mounted into a wall or a cabinet, the
recess must be 20 cm (8”) wider than the subwoofer to allow
sufficient clearance for the reflex port situated at the end of the
Short term amplifier output
power (Long term output power
is limited by driver unit
protection circuitry) 1000 W
Amplifier system distortion
Power consumption (average)
Free field frequency response 19 Hz…85 Hz
Harmonic distortion @ 105 dB SPL
at @ 1 m on axis in half space 30 … 85 Hz
Width 1440 mm (56 11/16”)*
(18 dB/octave) below 19 Hz
Upper bandwidth/LFE cutoff 85 Hz/120 Hz selectable
(sub/main channels) 85 Hz
Bass roll-off control operating From 0 to –6 dB @ 20 Hz
Phase matching control From 0 to 270° @ 85 Hz
protection circuitry) 1000 W
Input connector XLR female
Input impedance 10 kOhm balanced
Input impedance 10 kOhm balanced
Input level for 100 dB SPL
output @ 1 m Variable from +6 to –12 dBu
output @ 1 m Variable from +6 to –12 dBu
Output connector XLR male
Output connector XLR male
Remote LED connector (RJ11) Remote LED for
Remote LED connector (RJ11) Remote LED for
Main monitor Out gain 0 dB
Main monitor Out gain 0 dB
Input sensitivity +6 to –12 dBu
Input sensitivity +6 to –12 dBu
Bass roll-off 0/-2 dB/ -4 dB/ -6 dB@ 20 Hz
Bass roll-off 0/-2 dB/ -4 dB/ -6 dB@ 20 Hz
Phase 0 / 90 / 180 / 270°
Phase 0 / 90 / 180 / 270°
LFE/upper bandwidth limit 85 / 120 Hz selectable
LFE/upper bandwidth limit 85 / 120 Hz selectable
LFE sensitivity 0 / +10 dB
LFE sensitivity 0 / +10 dB
Redirect Redirects LFE channel signal
Redirect Redirects LFE channel signal
above 85 Hz to center channel
above 85 Hz to center channel
Sum in Changes subwoofer to
Sum in Changes subwoofer to
Test tone for phase adjustment 85 Hz
Test tone for phase adjustment 85 Hz
Genelec China Representative Office
Soho New Town, 88 Jianguo Road
D-1504, Chaoyang District
Comentarios a estos manuales